Marathon Max's lasting energy protects against battery failure, helping vehicle batteries stay strong and perform like new longer. BCI Group T6/LB3/91. form explosive air/gas mixture during charging. The BCI Group is not directly related to the performance of the battery. Follow good personal hygiene to avoid inhalation and ingestion: wash hands, face, neck and arms thoroughly before eating, smoking or leaving the work site. VIII. Rem, Batteries subjected to abusive charging at excess, SPRINTER MAX 12 volts Lead Acid 6-Cell H6/L3/48 Group Size 750 Cold Cranking Amps (BCI) Auto Battery. 96R-AGM. Prohibit smoking and avoid creation of flames and sparks nearby. A Group 96R battery is about 9.5" long while a Battery Finder Find the perfect fit for your application BCI Group 96R. Continue rinsing.
BCI Group BJ120. 0. No sm. Amp Hour Capacity (20 hour): 45. BCI Group 9BS. To add further context, the easiest way to tell if your vehicle was factory-equipped with a Group 96R or 40R battery (other than it being written on the battery label) is to check the length. Additional Health Data: All heavy metals, including the hazardous ingredients in this product, are taken into the body primarily by inhalation and ingestion. Keep away from heat/sparks/open flames/hot surfaces. Dispose of contents/container in accordance with local & national law, create a surrounding atmosphere of the offe. Also reacts violently with strong reducing agents, metals, sulfur trioxide gas, strong oxidizers, and water. This helps you understand how a battery can deliver energy over an extended period of time. Advanced grid technology paired with glass mat separators retains initial capacity for lasting energy for vehicle safety and entertainment features along with start-stop technology. 7439-92-1 7440-36-0 7440-31-5 7440-70-2 7440-38-2 7664-93-9 42-70 0.3-1.0 0.15-0.4 0.00-0.03 0.01-0.03 23-50 Case Material: Polypropylene 9003-07-0 2.5-10.5 Plate Separator Material: Polyethylene 9002-88-4 0.7-1. charged. Reserve Capacity Minutes (@ 25A): 90. Wear face and eye protection when near batteries being charged. Section 313 EPCRA Toxic Substances: Supplier Notification: This product contains toxic chemicals that may be reportable under EPCRA Section 313 Toxic Chemical Release Inventory (Form R) requirements. OTHER INFORMATION DATE ISSUED: March 5, 2017 OTHER INFORMATION: SOURCES OF INFORMATION: PREPARED BY: Distribution into Quebec to follow Canadian Controlled Product Regulations (CPR) 24(1) and 24(2). Contact with metals may produce toxic sulfur dioxide fumes and may release flammable hydrogen gas. Cranking Amps (@ 0C): 740.
BCI Group T5/LB2/90. Batteries being charged will generate and release flammable hydrogen gas. GHS SAFETY DATA SHEET I.
No further concern for mechanical impact. Wear protective gloves/protective clothing/eye protection/face protection. Ship fast and save more on MoparPartsGiant.com. Charging space should be ventilated. BCI Group Size describes the physical dimensions (LxWxH) and terminal configuration of the battery. Warranty Details ( 3 YR REPLACEMENT IF DEFECTIVE) DieHard Platinum AGM (Absorbent Glass Mat) batteries are specifically designed for today's power hungry vehicles. Use only outdoors or in a well-ventilated area. May damage fertility or the unborn child if ingested or inhaled. Electrolyte: Contact with combustibles and organic materials may cause fire and explosion. PRODUCT IDENTIFICATION MANUFACTURER/SUPPLIER Exide Technologies 13000 Deerfield Parkway, Bldg. Cold Cranking Amps (CCA) describe a battery's ability to start an engine in cold temperatures. EPCRA Section 312 Tier Two reporting is required for non-automotive batteries if sulfuric acid is present in quantities of 500 lbs or more and/or if lead is present in quantities of 10,000 lbs or more. Buy Econostar Automotive Battery, E-26R at Tractor Supply Co. Great Customer Service.BCI Group Size: 90 (T5/LB2) Cold Cranking Amps (@ -18C): 600. Call a poison center/doctor if y, all contaminated clothing and wash it before reuse. Store locked up, in a well-ventilated area, in accordance with local and. Exide's AGM (Absorbed Glass Mat) battery, Marathon Max, is designed to maximize energy capacity for today's on-the-go drivers. 200 Milton, GA 30004 CHEMICAL/TRADE NAME (* as used on label) *Lead-Acid Battery PRODUCT ID UN2794 FOR FURTHER INFORMATION CHEMICAL FAMILY/ CLASSIFICATION Electric Storage Battery Primary Contact: Exide SDS Support (678) 5669000 FOR EMERGENCY In the U.S. III. Reserve Capacity (RC) describes how long a charged battery can supply power without being recharged. More RC is beneficial for vehicles that aren't driven on a regular basis. Backed by Mopar's warranty, Car Batteries restore factory performance. Distribution into the EU to follow applicable Directives to the Use, Import/Export of the product as-sold. This helps you understand how much power the battery is capable of delivering in short bursts. Rinse skin with. This battery is ideal for vehicles with start-stop Shop OEM Mopar Car Batteries at wholesale prices.
The higher the CCA rating, the greater the starting power of the battery. Causes damage to central nervous system, blood and kidneys through. XVI. Shut-off power to chargers whenever not in use and before detachment of any circuit connections. contact lenses, if present and easy to do. COMPOSITION/INFORMATION ON INGREDIENTS Ingredient Inorganic compounds of: Lead Antimony Tin Calcium Arsenic Electrolyte (sulfuric acid/water/solution) CAS Number % by Wt. Many vehicles can accommodate a battery from more than one group size. If the existing battery is 96R then yes, our MotoMaster Group 96R (010-9672) will be a suitable replacement or you can consider our MotoMaster OEPLUS Group 96R (010-9680) for a Ost_. Lead compounds: Avoid contact with strong acids, bases, halides, halogenates, potassium nitrate, permanganate, peroxides, nascent hydrogen, and reducing agents. DieHard Platinum AGM batteries are engineered to provide up to 2x the life vs. a standard flooded battery. Most inhalation problems can be avoided by adequate precautions such as ventilation and respiratory protection covered in Section VIII. Explosive, fire, blast or projection hazard. CHEMICAL FAMILY/ Electric Storage Battery, Harmful if swallowed, inhaled, or in contact w, Causes skin irritation, serious eye damage. Rinse cautiously with water for several minutes.
Do not handle until all safety precautions have been read and understood.
prolonged or repeated exposure if ingested or inhaled. If exposed/concerned, or if you feel unwell seek, vomiting. Do not breathe dust/fume/gas/mist/vapors/spray. BCI Group T7 Part No. Keep battery vent caps in position.
- Peterbilt 379 Fuel Sending Unit
- Seadoo Spark Flush Adapter
- Water Dispenser Bottom Load Self Cleaning
- Best Tuner For 2018 Mustang Gt
- Rattan Round Wall Shelf
- Height Increasing Shoes 4 Inches
- Recycle Crt Monitors Near Me
- Waterproof Rubber Laminate Flooring
- Best 3d Printer For Terrain 2022
- Kinetic Folding Door Plans
- Plastic Outdoor Playsets For Toddlers
- Electrical Conference 2022