Thanks for considering them! Since the WEN impeller is "new" vs the Rikon impeller that's been popular I thought I would add these pics to the discussion. I think my HF unit is right at the limit of running on the 15a circuit because of the inrush of current. Please let me know if you have any other questions. https://www.etsy.com/listing/683808679/modern-and-mint-dust-collection-plans?ref=shop_home_active_1. One note that I'll add about the WEN impeller.
all my downspouts are piped back to the creek. Become an UNLIMITED member and get it all: searchable online archive of every issue, how-to videos, Complete Illustrated Guide to Woodworking digital series, print magazine, e-newsletter, and more. This is ingenious really, I am thinking about buying your plans but not sure if I am ready to plunk down over $600 yet. Running amps are about 12, I think, but haven't checked in a while. If I add an Oneida super duty cyclone for 150 and canister filter for 200 or there abouts, will my dust collector be up to the callenge of pulling dust from say 6 different drops (only one at a time ) in a shop 20 feet long by 16 feet wide? This is a reminder to those commenting on this post (not the person that posted it): Comments not related to woodworking will be removed. | Do Not Sell My Data
Violations to rule 1 including crude jokes, innuendo, sexist remarks, politics, or hate speech may result in an immediate ban. The plans include a full purchase list, instructions on breaking down the lumber, and step by step instructions on how to make the whole thing work. super dust deputy dust collector
I originally posted this on Lumberjocks, but wanted to post on other forums in case someone is looking for a small shop dust collector build, but is not on Lumberjocks. The link is here: https://www.etsy.com/listing/683808679/modern-and-mint-dust-collection-plans?ref=shop_home_active_14&crt=1. Thanks! Upload or insert images from URL. To bad you can't exhaust outside. To use a different tool, I just unplug the electrical and dust collection, wheel it away, wheel the new tool in place, and hook it up. Make sure the actual wire is good for whatever load you have. I was really tired of messing around with bags, and I didnt see a lot of designs that utilized a bagless design. In case anyone's been looking to upgrade their HF 2hp dust collector to a bigger impeller and having trouble finding the actual part, Wen's impeller is back in stock. It will take you to a form to fill out with your info and comments/request. Can confirm this part (3403-022) works great on my HF 2HP dust collector (97869 I think?). On the exhaust side is a Wynn Environmental 13F230NANO that is connected to a bucket. | Copyright
I am very surprised at how well the Harbor Freight motor does when its modified. Does adding that impeller cause the motor to draw a bit more current? Rabbeting a shelf; Strength vs. appearance, Editor's Letter: A new tool with every project. If you're like me, then you've probably already got some (if not all) laying around. You can now also by a fan from Wen Tools. wynn environmental
| Privacy Policy
minorhero, The Wynn Environmental Filter - Depending on how close to you live to Wynn Environmental, you'll likely save money on shipping. yea maybe one day I will regret it but I have had the motor mount not hooked to anything for almost three years now without issue but it was a concern when I put mine together. As I settle into my new shop I am beginning to think about permanent dust collection installation. With that said, Id love to see any type of improvements/modifications on this design if anyone decides to go ahead and build one like it. I was planning to do this before I saw the video. Please contact the moderators of this subreddit if you have any questions or concerns. I have been thinking for some time that Id like to get a smaller container for dust that is easier to empty. Start your 14-day FREE trial - and get building. I have an oddly shaped basement shop with a low ceiling and no good way to run ducting around the shop. maybe rotate the fan more towards the filter might let make it a more sweeping direct connection.
modification
Press question mark to learn the rest of the keyboard shortcuts, https://wenproducts.com/products/3403-022-turbo-fan-for-wen-3403. I needed a system that had little footprint and high dust collection capacity. No problem, glad I could help. I made this Thein/HF combo almost 8 years ago, and it works really well at catching everything but the finest particles. I currently run a Delta 1.5 hp collector, modified to use a thien baffle separator, and vented outside. Paste as plain text instead, I like this a lot. bagless dust collection The real motivator for me was having a cleaner shop space, and knowing that I plan to upgrade to bigger tools that require stronger dust collection in the future. You can post now and register later. My post is here: http://www.woodtalkonline.com/topic/21207-harbor-freight-dc-to-cyclone/?do=findComment&comment=237686. LJ will not be held liable for the actions of any user. DISCLAIMER: Any posts on LJ are posted by individuals acting in their own right and do not necessarily reflect the views of LJ. UNLIMITED Membership is like taking a master class in woodworking for less than $10 a month. Latest Forum Topics, Horizontal Cedar and Redwood fencing and gates, The Law Offices of Decker & Jones's Profile. Plus tips, advice, and special offers from Fine Woodworking. Currently I have the 2hp harbor freight dust collector and I have been moving it around to any machine I need to use. oneida super dust deputy The areas where I think the most money could be saved are: The 2hp motor - I bought mine new from Harbor Freight, and sold off the extra bits on Craigslist. I just need to get some circular too-its. Start your 14-day FREE trial - and get building! Can you post a link to purchase the plans? I made mine more compact since this and think I hurt my air flow so I need to back track a bit since I posted this and then changed it some https://www.lumberjocks.com/reviews/7842. I modified mine to a cyclone using a dust deputy. Looks nice the only thing I question is the angle of the dangle of the exhaust hose going into the filter. I love how compact it is. I have an un-modified HF dust collector and really dont like having a big bag of sawdust. I don't know about static pressure, but it did double my cfm's (at the tool). I don't see it on their 'parts' store online. http://www.dans-hobbies.com/2008/07/12/shop-made-dust-collector/. I certainly dig this. After some encouragement, I made plans and they are available on my Etsy for $10. Thank you. Thanks for that info Bob. The 20 Gallon Drum - I've got tips on finding these in your area in the plans, but if you can find one locally, you'll likely save money. I can buy a grizzly cyclone on sale for 750$ right now. After months of researching, I decided to build my own dust collection system. oneida air systems If you have an account, sign in now to post with your account. It is the Grizzly G0690 and for some reason the designers decided that putting the exhaust port 2 1/4" inch above the floor pan was a good idea. dust deputy 2022 The Taunton Press, Inc. All rights reserved. If it can work, any advice on going about it? Please submit links to how-to pages and videos, pictures of beautiful and amazing pieces you made for us to admire, or help you finish. I see the HF unit as a good bang for the buck for a decent basic DC and some minor upgrades like a cannister filter and maybe a Thien separator. Does anyone know a source? The plans include a full purchase list, instructions on breaking down the lumber, and step by step instructions on how to make the whole thing work. I have mine on a 20a circuit, a 15a might trip every now and then. MattCRNA I'm curious as to where you can order this from. Before: Startup amps, 14.27 Running 10.17. Have you checked into using a truck filter instead of a DC canister? They would probably be pretty unhappy with me if I vented directly into their front yard. Copyright 2021 The Wood Whisperer, Inc. I recently got my hands on a HB DC for a fair price and was hoping to upgrade it. I don't use the dc for small port machines, I just stick with a vacuum. However, there are a lot of opportunities to save money, and my build came in closer to $650. I will probably do this in the future. I apologize for semi-hijacking the thread. dust collector design If I vent outside it will be directly onto my driveway. Hey guys in regards to the WENimpeller go to www.wenproducts.com and scroll down to the bottom to the contact us button. Heres their number in case youd rather just call them directly: Hey man, thanks a lot for that info. I tested the startup vs running amps when I changed the impeller. Ive been using this system for a bit now, and it is so much more convenient. I do think it's possible to build this for even less than that. Really! I'd rather spring for a larger DC and run it on 220v. I will say it looks really straightforward, but there are definitely more pieces than anticipated. dust collector I have 3 drops, the longest is 37'. The run of ducting is very short. This system is entirely bagless, and has been extremely efficient so far. I only needed 3 drops, to handle the larger tools, I use a ducted central vac for all of my other dc needs. I don't want to be in a situation where I have to run a dedicated 120v 20a circuit for the DC. So that leaves doing it with a filter or having a really really really long exhaust port to vent it towards my garden instead of my driveway probably 25 feet of exhaust. Is it worth it to modify HF Dust Collector? It attaches to a Super Dust Deputy, which is connected to a 20 gallon drum. The cyclone and improved filter is obviously an improvement that I need as well. Click for full details. Great job of finding ways and means to make something that will fit your specific needs. Our biweekly podcast allows editors, authors, and special guests to answer your woodworking questions and connect with the online woodworking community. If you have any questions in the meantime, feel free to shoot me a message or post here. This time gave me the opportunity to finalize plans, and make sure I was finding the most affordable pieces. shop project Do you have problems with controlling the planer or table saw? Pulling 18.7 amps briefly at startup will probably not cause a 15 amp breaker to trip, there is a load / time curve they are designed to follow. I can completely understand. The whole thing is on wheels, and has the same footprint as a Harbor Freight Dust Collection system (22 x 33.). While lots of people modify the harbor freight dust collector, what is less clear is if it is worth it. The part number is 3403-22 just got mine today, installed and runs with no problems. It's probably drawing more like 100A initially on start up.
Normally, the Rikon impeller is the suggested upgrade part, but since those are apparently gone forever, this part seems to be a straight up equivalent. Get instant access to over 100 digital plans available only to UNLIMITED members.
Most meters will not react fast enough to show that though. I hope so, cause I just bought one. Terms of Service It was definitely a challenge, but I had a lot of fun. homemade dust collector The planer no problem, the table saw on the other handit is not a problem with the DC unit, it is a saw design problem. Powered by Invision Community.
It's the same specs as the Rikon fan but only costs $35 and shipping is fre, Hey guys, This site is protected by reCAPTCHA and the Google, Editor's Letter: Technology and the future of woodworking. (above the blade) But table saws are so leaky I still get quite a bit of saw dust in the cabinet. How did you go about ordering that? Repeated stops & starts in a short time might. Latest Blog Entries | I have 2 blast gates to control each leg of HF DC, in addition to blast gates at each drop. Edit: ordering the impellar is as simple as Matt said, just shot them an email and they responded within an hour or so with an invoice. Your previous content has been restored. The "all brand-new" price I quoted includes miscellaneous hardware and lumber. If you do modify with aThein or cyclone, I strongly recommend exhausting out side, I get very little to no visibledust, andthe noise reductionisfantastic. It's the same specs as the Rikon fan but only costs $35 and shipping is free. After months of researching, I finally decided to build my own dust collection system. Has anyone ever done a comparison of a Thien separator vs a cyclone? I may just turn out to be a plan buyer! The blast gates are all near each other, so closing the other blast gates isn't too annoying. I'll have to install a new circuit then since I picked up that Wen impellar. I do think this filter is going to last ages though, because it has over 200 square feet of filter and when paired with the Super Dust Deputy, barely anything goes through it anyway. By In-depth articles, up-close photography, and detailed illustrations. I do sell plans on my Etsy for $10. Etsy wont let me upload the SketchUp file, so I email that to purchasers after I am notified of the sale. I helped my dad make a Thein for his 2HP jet, and he loves it. I only used it once and just got the stuff for upgrades. 2022 Verticalscope Inc. All Rights Reserved. I needed a system that had little footprint and high dust collection capacity. I am a bot, and this action was performed automatically. With a Cyclone and venting outside. What's a good estimate on the all-in cost? Commenting has been disabled. Display as a link instead, I posted this over on my Instagram (@modernandmint) and several folks have asked for plans already. On the exhaust side is a Wynn Environmental 13R230NANO that is connected to a bucket. I understand trying to make it compact but seems like a better sweep would allow it to flow more air. I opted for a 20 gallon drum as it feels very space efficient, and I know it wont be overly difficult to move when its full. I'm no DC expert, so take this for what it's worth. You cannot paste images directly. This thing rockshttp://www.woodcraft.com/product/143290/trash-can-cyclone-lid.aspx. I opted for a 20 gallon drum as it feels very space efficient, and I know it wont be overly difficult to move when its full. 10X FLA is a pretty common starting current. This system is entirely bagless, and has been extremely efficient so far. On the other side of my shop is the property line with my neighbors being pretty close. Many of the better 2hp DC systems have 12" to 14" fans, and a true 2hp 220v motor pushing them. This was an absolutely huge project for me (both physically and financially), and I bought all of the pieces over a long period of time. The motor is a Harbor Freight motor that I purchased new, and then sold the remaining bits on Craigslist to help recoup some of the money. I don't think I can vent into my driveway where everyone coming and going from my house will be walking through the dust cloud in good conscious either. Or is this so far beyond the capabilities of such a setup that I am just throwing money away to even attempt it? I wondered if a larger impeller in the same fan housing might increase the pressure and force more flow through the restrictions. Good idea. It only has something like a 10" or 10-3/4" diameter fan, so I don't see it as the basis for a larger or much more complex systemit just doesn't have the initial airflow to make it worth going nuts with IMO. Clear editor. Enter now for your chance to win more than $2,000 worth of woodworking equipment from Woodpeckers. April's got a video on converting a HF dust collector into a Thien separator. Just an FYI for anyone wanting to upgrade their Harbor Freight dust collector fan. http://www.woodcraft.com/product/143290/trash-can-cyclone-lid.aspx. mobile dust collection. Shipping a filter from them to Portland, OR was expensive for me. And by running your cyclone during the rain, you can convince all the neighborhood kids to stay away from the creek, where the waterspout monster bubbles and blows! I knew itd be possible to make what I wanted, I just needed to identify how. Ive also attached a pdf copy of the WEN dust collector manual that I used as a reference for the impeller info. I just got mine in today, and I haven't done the swap myself yet, so YMMV, but for $50, I was willing to take a flyer on it. I agree that rotating the motor may eek out a bit more air flow, but I wasnt worried about it when I built it. Check this thread: http://lumberjocks.com/topics/148882, it might be a way to reduce the cost. it won't compete with a multiple HP unit, but considering i only paid ~$100, I've more than got my money out of it.
My guess is"no", since if you've got one why buy/build the other? However, I see 2hp motors/dust collectors come up on Craigslist or Facebook Marketplace pretty frequently for about $50 in my area. Each blast gate also has 220 and 110 outlets near it. Pasted as rich text. Latest Projects | http://www.woodtalkonline.com/topic/21207-harbor-freight-dc-to-cyclone/?do=findComment&comment=237686. mobile dust collector UNLIMITED membership - Get access to it all. mod Anyway I am slowly modifying the saw to solve most of the problems. Just an FYI for anyone wanting to upgrade their Harbor Freight dust collector fan. You can now also by a fan from Wen Tools. Future project for me. The most expensive items are the Super Dust Deputy, the motor, and the Wynn Environmental Filter. I've se. I'll make the Thien separator when I get a round too-it. My plan is, I set up the DC near my table saw with a permanent duct to the saw and a blast gate. But I want to go ahead and install ducts and have a more permanent setup. How does your system handle your tools? https://wenproducts.com/products/3403-022-turbo-fan-for-wen-3403 It's $50 with free shipping. Did you have to call Wen directly? If you were to purchase everything brand new, I think the build would run approximately $800. Then, I put all of my tools on rolling cabinets or bases, and plumb each tool so that whatever dust collection it has, it ends in a short length of 6" flex duct with a quick connect. However, if the area is reduced, such as when using a zero clearance insert in the tablesaw, or stepping down to a 2" port for my spindle sander, the air flow drops drastically. no bags dust collection My shop is 30 x 17 and for my set up the HF is probably all I will need. The motor is a Harbor Freight motor that I purchased new, and then sold the remaining bits on Craigslist to help recoup some of the money. Thank you! I haven't seen any threads on WTO about it but there a number of people over on lumberjocks that seem to like it. | Ive had really positive feedback on the plans so far.
I assume that a Thien will be "good enough". Id love to add the Rikon impeller in the future, but I have concerns about it pulling too much power with my current electrical situation. I will say it looks really straightforward, but there are definitely more pieces than anticipated. This way, I can always use my table saw, and I can have three other tools set up and ready to go, without a lot of ducting. If anyone has recommendations on where else to post the plans for sale, Id be interested. The reason I didnt rotate the motor more is because I wanted to use the stock motor mounts to bolt into the side of cart instead of trying to design something else to hold that motor in place. After posting this over on my Instagram (@modernandmint), several folks asked for plans. I see people adding canister filters and cyclones, but do you get comparable suction to similarly priced 2 stage production units? Is it OK to copy projects from the magazine? Ive made an update thread here for anyone who wants updated information.
With that said, I d love to see any type of improvements/modifications on this design if anyone decides to go ahead and build one like it. Your link has been automatically embedded. Is there anything cheaper then the Oneida super duty?150$ seems like a lot to pay for a plastic funnel. That's real helpful and I'm looking forward to picking one up this week. The whole thing is on wheels, and has the same footprint as a Harbor Freight Dust Collection system (22 x 33.). Collection is quite good, so long as there is adequate area of air flow across the source of dust or chips. The system you created is very similar to what I had in mind only I was going to do more drops and use blast gates as early as possible in the system. I had to download the manual for the dust collector to get the part number which is 3403-22, this is also where I found the specs for it to see it was the same as the Rikon impeller. I also have a 2HP Jet DC which isn't really powerful enough to pull a multi-tool ducted system. I had an absolute blast making this, and I wanted to post this as my first project on Lumberjocks. Yours looks about right to me. diy collector So this leads me to an interesting thought. (I don't think many table saws have well designed DC.). Actually using the dc Iam very pleased. /r/woodworking is your home on reddit for furniture, toys, tools, wood, glue, and anything else that has to do with woodworking as a hobby or profession. This is awesome! harbor freight This forum post is now archived. To me, this seems like a better solution than rolling the dust collector around to each tool. The PDF plans are digital download straight from the purchase. I did a google search and didnt find one from Wen but did from Ricon. Once you get the collector, cyclone, and the filter? Press J to jump to the feed. no bags dust collector If memory serves, I'm in my second motor, and I've replaced a bearing or 2 over the years. It attaches to a Super Dust Deputy, which is connected to a 20 gallon drum. Manage Consent. I had to keep the same 22 x 33 footprint since my shop is so small. For anyone who has done this mod, a questiondoes the new impeller provide any increase in static pressure for the system? Get complete site access to video workshops, digital plans library, online archive, and more, plus the print magazine. At the shortest drop the loss is 12%, next is 20% and the longest % is 25%. I have a cheapo anemometer that I used to find out how much air flow is lost compared to the intake at the dc. March 11, 2016 in Power Tools. I drill holes in my zero clearance inserts which seems to help with saw dust accumulation at the table saw. Their pn is 60-200. We have created these special content collections organized to give you a deep dive into a range of topics that matter. Could i pipe my exhaust into a down spout and by the time it rains it will just was the fines out to the creek? I also run a short (maybe 15 foot) 6" duct along the wall, with a wye and a blast gate every 5 feet.
- Hayward Basket Strainer Parts
- Zara Jacquard Pleated Pants
- Wrap Around Clawfoot Tub Shower Curtain
- Serena And Lily Bedroom Chairs
- Comfort Suites Medical Center Fargo
- Zemi Beach House Wedding
- Nylon Sewing Thread Near Me
- Ge Paintable Silicone Supreme Home Depot