I plug it into another outlet (same voltage) and it starts. JavaScript is disabled. First, it is good to check that you are ordering the correct pump model, especially if you do not have a technician. If your pump has a label on the side, the voltage should also be listed there. You could avoid a technicians services while installing your pump by purchasing a replacement hot tub pump online. waterway discharge 230v 0hp A split capacitor (start and run) allows for less energy consumption.Spa Pump Features: All 3 of my pumps in our CalSpa are dead and need to be replaced. 22 0 obj <> endobj xref 22 51 0000000016 00000 n And each year, he continues to help more people with water chemistry, cleaning, and troubleshooting. If you need a solution to quickly suck up any debris thats causing problems inside your hot tub, I recommend the Workshop wet/dry Vacuum.

You should also check that the jets of your pumps are open inside the hot tub.

The holes are farther apart or closer together depending on the size of the frame, so if you choose the wrong size frame, you wont be able to attach it properly. This is the ultimate maintenance guide that hot tub manufacturer doesnt provide you. Reply, i need the 2 hose adapters where the drain plugs are at 9 and 6 o`clock i cannot find part #`s for these i did not know they were not included Just an FYI. First, look for the sticker on your old pump to determine the specifications. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Its about 15 years old. Key Lander Hot Tub Spa Circulation Pump; 48Frame LX Motor (115V OR 230V/60Hz); One Speed; 1.5 Port; OEM Model # 48WTC0153C-I, KL KEY LANDER Hot Tub Spa Pump, 1.5HP, Two Speed, 48Frame LX Motor (115V/60Hz); 2 Port; OEM Model #37334-03; 48WUA1001C-II, NEW KL Key Lander Hot Tub Spa Pump, 4HP, Two Speed, 56Frame LX Motor (220-240V/60Hz); 2 Port; OEM# #0982601-03; 1431601-03 and 56WUA400-II, Waterway Plastics 3722021-1D Executive 56 Frame 5 Horsepower Spa Pump, 230-Volts. And the cycle will be repeated. 0000026253 00000 n 0000002388 00000 n In fact, some wont even fit where your old pump did. 0000002647 00000 n Youll be able to tell which one your pump is just by looking at it. wet end 0hp executive frame allied I need to find the replacement pump for the whole unit. The normal life of most spa pump motors is about 5 years and if your pump is older than that, spa pump replacement may be the better long term solution. You may try contacting their customer service to order the correct part. When one component has a problem, its possible to repair each end separately. Once we get those photos we can make the proper recommendation. The location on your pump where water exits is the discharge orientation, and it will either be in the center (on top) or on the side.

You turn on your spa and hear a screeching sound. You'll save $100 right away with this easy-to-follow digital ebook and video course. | This hot tub Spa Gate Slice Valve might come in handy if youre looking to cut off water from the pump to the rest of the hot tub. Some pumps require you to close the valves on the intake, and the pump lines outflow before draining the hot tub. When you notice that your hot tub pumps have failed, it is always good to start by checking the possibilities of power trouble. Thermal creep occurs when hot weather causes the hot tub temperatures to exceed the required minimums. 0000049914 00000 n Next, debris can be quickly cleared from the suction valves inside the hot tub. The heat is then transferred to the water inside the hot tub, making the water overheat beyond the required limit if not adequately monitored. Cheers, Mark Double check your water level to make sure the tub is filled properly. Locate your breaker box (usually a metal box mounted on a post or the side of your home, a few feet away from your spa). 0000036988 00000 n Heater Info on Spa Heater Elements, Spa Heaters, Hot Tub Heating Elements. The Executive 56 Frame Spa Pump has an executive wet end designed for 56-Frame motors along with two double-shielded ball bearings with moisture-resistant grease for quieter operation and long life. Find priming mode on your control panel (if its available). Circ pumps, as theyre commonly called, only move between 25 and 35 gallons per minute (GPM). If the fuses are okay then unplug the pump from the pack, insert the meter probes in the socket and turn the power on. By continuing to use this site you consent to the use of cookies on your device as described in our, By continuing to use this site you consent to the use of cookies on your device as described in our, Please type your question in the field below. i ordered a new one but I'm not sure it's correct. 0000039862 00000 n %PDF-1.5 % Trapped air, lack of pressure, or a pump that wont prime may be the culprit. These pumps will also show two different amperages on the data sticker. Each end contains parts that can malfunction and cause pump problems. 0000037067 00000 n The problem of a hot tub not working could be associated with electrical malfunctioning. of waterway speed 56f 4hp executive pump tub parts But if you havent found any physical reason for your water pressure to struggle, your pump might need further inspection. The stainless steel construction and 16-gallon capacity will make cleaning your hot tub much easier. This means that further repair is not required, but a replacement is needed. Reply, Hi, Ray. If you find it difficult to troubleshoot the issue, check the electrical system, the valves, possible overheating, scale buildup, and debris blocking the water circulation. The power of the pump determines strength of the water jets and the massaging action. If youre having heating problems, check out our full article on hot tubs not heating for more information. 0000030479 00000 n Other specs, such as discharge type and size, can be determined just by looking at your pump. 0000012733 00000 n Airlock issues are caused by large air bubbles within the plumbing. One of the warning signs is the increased difficulty in adjusting the jet nozzles. Keep in mind that the average life of a pump is 5 years.

Tip:Some pump brands use non-universal fittings for the discharge. waterway executive 1d pump spa frame volt plastics hp 0hp discharge 230v speed side If youre wondering how youll determine which size spa pump you need just by looking at the old one, dont sweat it. Every hot tub needs a pump that can power the jets and circulate the water. The hot tub pump not working correctly can happen at any time. The slow water flow prevents the heater from working correctly. If the problem appears to be internal, youll may need to replace the motor entirely. Reply, What kind if connector is on the plug? I have an EO2 message while it's, Should the spa pump be on continuously.. we have just, SoftTub Spa pump issue. You are using an out of date browser. If the blower still does not switch off the problem could be with relays on the circuit board have frozen, in which case you may have to replace the board. Most pumps let you turn discharge to orient it however your spa requires. only have 120 volts at the 220 volt pump. As you can surely guess, the wet end houses the impeller which pushes water through your spa circulation system. The same buildup could be taking place in your hot tub plumbing and pump system. Grab a flashlight, open your spa cabinet and take a look around. Replacing your hot tub after it has reached the end of its life will save you unnecessary service costs and allow you to continue enjoying the hot tub. If you have separate circulation and jet settings (two pumps), your pump is likely single speed. Case Details: It starts in high speed after which I can set it to low. Should the spa pump be on continuously.. we have just refilled ours and trying to work out the setting. Reply. Shut off the power and open the control box.

Loosen the intake and discharge fittings. If there isnt one, you can get the information yourself. If the problem is with the start windings I feel that rewinding them is not a worthwhile option on any motor. If you hear gurgling, bubbling noises, it may indicate trapped air trying to escape your jets. To fix an airlock inside a hot tub, you must first turn the water temperature down by at least 10 degrees. Reply, Does this include pump and motor If the old pump continues to work, let it be and keep the new pump as a spare. The two wires are typically green and white. The dual speed motors have insulated windings for increased efficiency and large, highly versatile 6-1/2" diameter wet end for higher head pressure. One of the warning signs is the foaming of your hot tub water based on the pumps not filtering correctly. If the meter shows that power is flowing to the pump cord, then the like problem is a defective pump. Digital Multimeter with Ohm Volt Amp and Diode Voltage, Waterway Executive Hot Tub Pump Impeller - 4HP. Most spa pumps are specially labeled.

Case Details: It becomes louder in the 2nd speed and stops when I switch the pump off. Well, stop that. Clean your leaf trap and filter first, then try priming the pump. Youll not only want to repair the source of the leak, but check to see whether water has destroyed any electrical components inside your spa. If you find anything gunking it up, clean it off, and try your pump again. The expert will use a more technical approach in resolving the problem with the pump. I've located it, but mine has two nipples in the front for hoses. Turn your breaker and spa back on to check the jets.

Access your hot tub pump and close the gate valve on the discharge side. Please take a close up shot of the motor label as well as a wide shot of the complete pump to include the pipes going in and out of the pump. 0000002252 00000 n 0000050627 00000 n Tighten the fittings, first replacing unions and O-rings if necessary. If not, you can simply measure between the bolts on the frame, or on the motor. If youre lucky, this might be all you need to do. 0000044770 00000 n The Hot Tub Handbook and Video Course will help keep your hot tub balanced, sanitized, and crystal clear all the time. A hot tub pump can overheat because of blockage and other electrical, plumbing, and valve problems. The motor part # is 3721621- OD76.Waterway Model PF-30-2N22M. 0000025732 00000 n You will get much more visibility by. 0000019453 00000 n Copyright 20XXSpa Pumps And More. Thank you! Stop wasting time and money with hot tub maintenance and confusing water chemistry! hot tub water based on the pumps not filtering, https://www.youtube.com/watch?v=GS_SO4YhWcM&ab_channel=ehowathomechannel, How to Fix an Air Lock in Your Spa : Pools & Spas (https://www.youtube.com/watch?v=GS_SO4YhWcM&ab_channel=ehowathomechannel), https://www.youtube.com/watch?v=7o2gbvl8Mnw, HOT TUB Pump Not Working? Instead, it will take time before you start noticing a decline in your hot tubs performance.

6 Common Problems & Fixes | Swim University (https://www.youtube.com/watch?v=7o2gbvl8Mnw), check out this great article from swimuniversity.com, The speed, which could range between 1 and 2, The connection size, which ranges between usually 1.5 and 2.5 inches, Orientation, where you will check whether the pumps discharge has a central, left, or right discharge. Reply, I am trying to match up my old pump, it is an Executive 56 5HP 230V 12.0/4.4amps, Part # PF-40-2N22C Reply, Mark : The spa pump has 6HP tag on it, and the following numbers in the plastic casting 311-1239-DNB - 311-1200. Otherwise, your motor may be irreparable and need to be completely replaced. Which one would be the right pump, motor combination to replace it with?

If it does trip, your pump is probably fine, but youll need to troubleshoot the breaker itself or call a pro to take a look at your spas electrical components. Since hot tubs are designed to prevent heat loss, the temperatures will continue to rise during the hot weather because there is no way the heat will escape from the hot tub. Run the jets on high for about 15 seconds. It may not display this or other websites correctly. Check to ensure you have turned on the power switch after filling the hot tub. I recommend the AstroAI Digital Multimeter to test any internal electrical issues if you feel comfortable doing so. Finally, turn on all the pumps until the water pressure returns to normal. 120v spa pump runs on low for 60 seconds beforepump motot relay shuts down but it runs on high with no problems, low speed test at board red to black 120v,black to common 120 v,& black to ground 120v. Even self-priming pumps may sometimes need a helping hand. You should be able to find one of those numbers on your pumps sticker. The effect of the scale buildup may not be immediate. A damaged impeller may also fail to turn properly, which may require you to replace the impeller itself. Hello Eric, Yes that pump Waterway Executive 56 Spa Pump - 5 HPdoes come with the seals as it is a whole pump and motor replacement. First, clean your filter and leaf traps.

Reply. If you can turn everything on, but your water isnt circulating, you could have a stuck impeller or a clog somewhere in your circulation system. Remove the cap and check the connections. Reply, Hi, Is this pump suitable for salt water?

You've taken your last lukewarm soak. Your jets kick on, but barely any water comes through them. A hot tub pump not working correctly may be caused by electrical issues, airlocks, or debris blockage. The capacitor is usually on top of the motor under a cap. If this is the case with your new pump, youll need to replace the unions when you install the pump. Hello , This is an inactive thread. Get a repair estimate and then take a repair or replace decision based on the repair cost and residual life of the pump versus the cost of a spa pump replacement. The motor in your spa pump needs power to function. They can also trip the hot tub breaker, fry your motor, and rust or corrode electrical components. customers would recommend this product to a friend. Before you try to fix or replace a malfunctioning pump, familiarize yourself with the specifications of your hot tub pump. Any new postings here are unlikely to be seen or responded to by other members. It. hi i my spa pump shuts down after 30 sec and I see 888 flash as a code? This free printable cheat sheet helps keep your hot tub clean and clear without messing with confusing water chemistry. And, Viking spa 54350-01 control board spa pump runs low speed, 120v spa pump runs on low for 60 seconds beforepump motot, My swim spa pump has been running 24/7. Blockages can cause overloading and overexerting the pump, making it overheat. You can take the cord off of your old pump and attach it to the new pump. Its natural for them to wear out and need to be replaced over time, but if you take care of your pump, itll keep your jets massaging for a good, long time. 0000053964 00000 n

Reply, Hi Gary, yes this wet end can be rotated for easy installation. 0000001717 00000 n

Your situation is that the control panel thinks the spa pump is working when it is not. But water inside your spa cabinet or near your GFCI is far less of a good thing. The bleed plugs are removable & the part #'s for the barb replacement plugs are 9404-01 & o-ring # 4600-4661 0000018161 00000 n The electric motor pumps water around the hot tub through the jets, filters, and heats the water. I have an EO2 message while it's beeping. If there is a short in the motor wiring, it could cause your breaker to trip, seemingly at random. You should also check if your remote hot tub controller does not override the switch being used to control the pump. If the first method didnt work, you can use your pumps bleeder valve to get rid of air. You could also look at the water filter leaf trap in the pump lines intake to ensure no clogging of debris. What Is a Pool Aerator and Are They Worth It? Voltage out from receptacle is 121.2. Be sure to start with a line flush product to purge your circulation system of any gunk. Too much power through too-small pipes will limit power and could even cause leaks. Clogging problems will usually occur when water filtering is taking place in the hot tub. Waterway Spa Pumps, Waterway Pump Parts, Waterway Bath Pumps, Waterway Circ Pumps. Many times the labeled Horsepower does not accurately represent actual horsepower. We have spoken with customers that have had issues making the newer style work with the older style volute. The specs you should compare for your new pump could include: Its good to note that most new pump models do not come with a pump cord. A spa pump is a complex piece of machinery and the instructions in the owners manual should be followed when attempting spa pump troubleshooting, repair or replacement. 1 0000018579 00000 n Spa pump not working, display says ALARM over current. If you see the tripping of the GFCI, you can restore the power by pressing the red button. By the way, we do currently have these pumps in stock ready to ship! But the motor generates heat when running. Water not moving properly? 0000030198 00000 n Additionally, it forces water through the filter to removes dirt and debris. Leaks may cause your hot tub pump to malfunction. Make those simple practices part of your routine and youll enjoy worry-free soaking for years to come. 0000018936 00000 n Stop wasting time and money with hot tub maintenance and confusing water chemistry! Thank you, Hi Carlos, the complete pump replacement for your pump model number06118371-2 isAquaFlo Gecko Alliance XP2 Spa Pump part number5121-316. When you add water to an empty spa, air can get stuck in your circulation system. It decreases the ability of the pump to push water through the main lines. 0000054259 00000 n Reply, Hi Mike, the drain plug for the Waterway Executive 56 spa pump is part number 5039-001and they are included with a completely new pump. That power must be accommodated by appropriate plumbing.

This may cause the pump to shut off completely.

If its not, youll need to clean off any corrosion, or possibly even replace the wiring.

0000016140 00000 n Reply, Hello John - The pump does not come with a cord. The replacement for your spa pump is AquaFlomodel061205002040. The most likely cause of this problem is a bad start capacitor which acts like a starter on a car. Some hot tubs have single-speed pumps, but in those cases, there are two pumps. We are a registered 501(c)3 non-profit that is funded by user donations. Tip: When replacing your hot tub pump, save the power cord from your old pump (if its operational) to use on the new one. Built with Volusion. Gently move the pump so you can reach the wires and detach them. Reply, Most often these leaks are caused by failed seals and gaskets but in order toconfirm which ones you will need, you will need to know the specific pump make and model. Reply, You can remove the plugs and insert the adapters for the two nipples. Also, check out our full article on hot tub jets not working for more information to troubleshoot your spa. But these are not the only reasons that your hot tub overheats. 0000016000 00000 n Reply, I need a replacement for a Cal Spa hot tub (GE Motor Model 5KCR49WN2370AX). Make a habit of looking for moisture around pump seals before the problem grows. 0000032983 00000 n

Thermal creep is the most common cause of overheating in your hot tub pump. I am looking for the front portion of the wet end. Make sure you know what to look for to choose the best replacement hot tub pump. If you dont tighten it, water can leak here and cause problems, so be sure to replace it properly. Now both will now not turn off. The problem is likely to be with the centrifugal switch in the pump motor or the start windings becoming worn out. Improper functioning of your hot tub could result from scale buildup. What I have found only has plugs in those location. 0000039793 00000 n Sometimes it takes multiple tries through each of the priming steps to properly prime the pump. 0000026076 00000 n As the priming process differs slightly from model to model, youll want to check your manual for specifics. A Quick and Easy Guide to Hot Tub Ozonators. 0000017342 00000 n Youve got no power coming to your spa.

Or the starting capacitor wires could be loose causing the on again off again performance. 0000050602 00000 n If the wiring is corroded, look for leaks. Will it come with new seals as well? 0000044691 00000 n To fix this, make sure there are no electrical problems with the breaker, motherboard, or pumps inside the hot tub. If youre comfortable doing so, you can use a multimeter to check whether the wiring is actually delivering steady power to the motor. Most pumps have a label on the side listing the most important technical aspects, such as horsepower (HP) and speeds. Here's everything you need to know about whether you need a pool aerator and how it affects your pool. At the moment it is on low setting all the time. In order to keep it moving water without frying the motor parts, every pump has a wet end and a dry end. The dry end contains the motor in a sealed housing that protects it from moisture. Grinding noises are a hallmark sign your impeller isnt rotating properly due to residue or electrical issues. If the bolts are closer than 4 inches, its a 48 frame. When you turn off the pump when draining and refilling the hot tub, the loosened debris could clog the jets. Can I go lower HP and Amps to get cheaper motors or do I need to stay about the same? But you can still use the cable from your old pump if it is in good working condition. Others have brand-specific connectors. If you make sure you buy the correct replacement pump, and you dont have any other problems with your spa, installing the replacement pump is fairly simple. When a single pump can switch between high and low speeds, its called a variable-speed or two-speed pump. This most commonly occurs right after refilling your spa. Repeat the jet bursts three times, increasing the run time by 1015 seconds each time. Even small variable-speed pumps typically move 100 GPM or more. Of course you want water inside your hot tub. Also, make sure all the jets are fully open before you begin the cleaning process. HW$}ED&i/?cH?Uz2tV}~{,3Vm|Q6+G)o?M)OJrZ&ISN||S)=|?;pkS6{8|8Ny[}uys~}f+y.]>_n(c`ioO?A$Jy-Q0#AO2qzO:z_uoJay=*/?>_~}l{57GJd~GP@61[w>vW=JWGQ } 3eQG$^nz5G]Vk BPq6^a15)^Zx]5PPo, WbV;Pf7_a?l |l`ZO{. Resolve this by running the pumps with the jets fully opened. I have a cracked wet end on a spa pump. Reply, Hi Dave, Yes this can be rotated so the discharge port is at 90 degrees. Thanks: Ray Ask an Expert online. For more information on hot tub pumps, check out this great article from swimuniversity.com. These can be single or variable speed. Thus, you may notice a lower pressure or decreased output from the water jets. A spa pump has is used to create the thrust for the massaging jets of water and bubbles that are to be found in spas. I have an idea of what the problem might be but would like another opinion. But most of the time, its less expensive to just replace the broken pump entirely. Filtering can affect the hot tub lines and the pump. One is called the circulation pump, which runs at a much lower speed and uses less energy than any other pumps. You must match the specifications to the manufactures specifications for the type of pump needed for the hot tub. When matching pumps always use AMPERAGE rather than Horsepower. You could also call an expert to help you replace a hot tub pump if you experience any difficulties. Most visitors online was 3404 , on Jan 24 2020, New start and run capacitors, but pump motor still fails to start every few days, Century 2 speed pump drops to low speed, runs 3 to4 minutes then just shuts off, Pentair 2 Speed Pump Won't Start on Low Speed (Only), With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Hot tub pumps come in different sizes and specifications, but the hot tub pumps I recommend are theWaterway Plastics andKL Key Lander pumps. You could check the label of your existing pump to know what you are going to order. Fresh water, a deep clean, and dedication to water maintenance and hot tub cover use can go a long way toward preventing spa problems and solving water pressure issues. The two basic methods are easy to do. Its advisable to call an expert when you cannot fix the airlock problem or change your hot tub pump. ?? You're not still lumbering into your spa by climbing over the edge, are you? The pumps may require 2 to 3 cycles before the water pressure returns.

If the distance is more than 4 inches, its a 56 frame. Pump will not start after two uses use from same outlet. The wires would be green, white, black, and red. Your hot tub pump is the thing that makes your spa a spa, rather than just a big bathtub you share with othersawkward. When air bubbles out of the jets, leave them on until the bubbling stops. But there are a few things you need to bear in mind when ordering a new pump. Not all pumps are created equal. Reply, Hi Brian, This pump is complete with motor and wet end.

If not, you can buy a suitable cable from the available range of AMP, J&J, and mini J&J, among others. Close the valves or drain your spa, so all the water wont run out when you remove the pump. This means it needs both high and low speeds, which are measured in revolutions per minute (RPM). The debris blocks the water flow in the hot tub and prevents the suctioning from working effectively.

Some twospeed pumps can even be configured for single-speed use in a spa that has a circ pump. If the basic methods of removing the airlock, checking electrical issues, and cleaning the hot tub dont work, you should consider calling an expert. Learn more, We use cookies to give you the best possible experience on our website. If you see any moisture, locate the source. Reply, Can the wet end be rotated 1/4 turn or 45 degrees jets will not run when temp is at setpoint. Its important to determine whether yours requires 110120 volts or 220240 volts. And about every 15 seconds it clicks and shakes piping. Pool and Spa Experts on JustAnswer are verified through an extensive 8-step process including screening of licenses, certifications, education and/or employment. If the water level is too low, you may have problems with water flow. Disconnect the 2 or 3 wires that connect it and fit a new capacitor connecting the wires in the same sequence. This process of noting the HP a pump can achieve in the factorybut not in your spais called up-rating. He followed up with me by phone the next day to check on her. 0000001618 00000 n If your pump has only two wires powering it, its 110120 volts. Dont give up after one priming try. Airlocks are formed if you have recently filled your hot tub and there is very little or no pressure coming from the jets. You should check the manufacturers manual on how the valves should be kept. 0000132752 00000 n 0000053562 00000 n The development of airlocks in your hot tub interferes with the regular operation of the jets. My pump has 3 round pins in a diagonal (/) pattern and 1 flat pin that plugs into a LA Spas control center. I greatly appreciated the personal contact and follow up. Waterway pump diagram, Waterway pump repair. Reply, Good Morning Mark. He firm we bought it from set it originally. Matt Giovanisci is the founder of Swim University and has been in the pool and spa industry since 1995. Next, set all the jets in the spa to their open positions allowing for maximum water flow. If you click this link and make a purchase, we earn a commission at no additional cost to you. To supply photos simply click the reply link below and upload your photos. Stop wasting time and money with hot tub maintenance and confusing water chemistry! The housing around your pump includes pre-drilled holes where it will be bolted into place inside your spa. Flip your circuit breaker to avoid accidental contact with electricity from your pump. If you can adjust jet intensity and circulation you have a variable-speed pump. Its important to know how to spot signs of trouble, what steps to take to circumvent preventable problems, and what to do when they crop up. If it is an airlock problem, they could untighten the pump system to help bleed the air out. The sound can also result from a broken impeller and dirt in the hot tub filter. It is being practiced by thousands of pool owners just like you. 0000019478 00000 n i ordered a new one, My spa pump is not working.

Sitemap 12